Information Name: | Humidity curing box |
Published: | 2015-04-21 |
Validity: | 0 |
Specifications: | |
Quantity: | 10000.00 |
Price Description: | |
Detailed Product Description: | YH-40B / 60B / 90B Standard temperature and humidity curing box I. Product Overview: YH-40B / 60B / 90B Standard temperature and humidity curing box is based on national GB1345-99 "standard consistency of cement setting time and soundness test water Technical Information Development Design "and the National Building Materials Institute and the relevant departments to provide manufacturing for large, medium and small cement plants, construction and construction engineering department for concrete, cement specimens condensation conservation purposes. On the basis of the original products, a series of improvements, the door closed using magnetic tape, better insulation layer insulation cotton insulation, internal addition of refrigeration units, smooth running, low noise, and a heater for machining brass into, rust and corrosion, humidification device, attractive appearance, high precision controller controlling temperature and humidity series of advantages in the use of an additional explanation of the user fault repair table exclude themselves, as the users in the maintenance records for the factory to provide a basis for so I plant conservation boxes in the production process can be improved to make the products durable meet user requirements. Second, the temperature and humidity conservation tank main technical parameters: 1, temperature control, humidity control: more than RH90% 2, controlling the temperature: 20 ℃ ± 1 ℃ 3, the power supply voltage: 220V 50HZ 4, heating power: 1000W 5, cooling power: 145W 6 humidification power: 45W 7, humidification capacity: 400 ml / hr 8, humidifiers volume: 5.5L 9, inside the space: 40B-type concrete block 1503 can put 15 groups can be put 60B type concrete block 40 1503 Group 90B type concrete block 1503 can put 60 groups of three, temperature and humidity conservation tank structure and working principle: a structural box with outer and inner layers, from outside the box and inside the box, outside the box of high quality cold-rolled steel within the box with stainless steel plates, stainless steel shelf profiles made good corrosion resistance. Within the cabinet below the tank for heating and auxiliary humidifier, ultrasonic humidifier humidifier instrument-based systems, water heating evaporation, supplemented by automatic temperature control system and control humidity meter instrument at a given temperature, humidity refrigeration heating and humidifying the implementation of automatic switching, inside temperature and humidity displayed by the meter number. 2, the working principle of the thermostat: When the inside temperature is lower than the lower limit of the setpoint temperature controller, the temperature controller output signal instruction electric heating original start work, and vice versa when the temperature is higher than the upper limit of a given value, temperature controller instruction Cooling System work, when the inside temperature reaches the required specifications, automatically stop heating or cooling. Wet control: Using ultrasonic humidifier humidifier can guarantee inside humidity reaches ≥95%, by the temperature automatically controlled humidification device, when the humidity is <95%, temperature controller instruction humidifier working to achieve the return difference After automatically stop working, the difference should be adjusted back at 0-1 ℃, easy to be too large. Fourth, the temperature and humidity curing box Usage: 1, box in place, leveled, take a good ground, still 24 hours, add clean water to the tank, the water level exceeds the heating pipe. 2, open the door, remove the humidifier. Open the door, put the humidifier on the tray, remove the transparent water tank, in turn, counter-clockwise rotation into the water tank cap, fill clean water (distilled water is best), Sheung Shui After adding water spin cover, back by Wet is the mother, and then press the nozzle humidifiers, humidifier finally plug into the outlet side door. Turn the power switch, the spray knob to adjust to the maximum position. Conservation tank temperature controller temperature, humidity factory has a good tune. 3, the power, the instrument to work, to be inside the temperature and humidity reaches a given value, and then into the specimen, heating and cooling at the same time is prohibited. Fifth, the temperature and humidity conservation tank main issues: 1, conservation tank should be ventilated, dry, smooth, non-corrosive environments, daily use to keep the water tank, the water level in the humidifier to ensure the normal use. 2, after conservation tank in place, the need still 24 hours before being powered on, the voltage is lower than 160V or higher than allowed 240V, voltage instability will burn control device, you must use power supply. 3, the compressor does not start frequently, cooling power or stop work must be spaced five minutes, and then began the second start, in order to avoid damage to the compressor. 4, the device allowed upside down, so as not to mix compressor lubricants and refrigerants, refrigeration unit damage. 5, not tilted 45 degrees handling. 6, insulation test before work, in order to avoid the risk of leakage. 7, the addition of water in the tank is 40 ℃ best six, temperature and humidity conservation tank Common Faults and exclusion method: 1, the instrument displays do not work (1) Power is not turned on, check the fuse and plug. (2) the power switch to the bad, replace the switch. (3) meter output line off, the plug is not seated. (4) contact burn-out, replacement of the same type of contactor. 2, no refrigeration (1) temperature controller setpoint is correct, temperature controller output signal is not given value or it is set to check temperature controller fuse. (2) temperature controller output signal contacts does not work, for contacts. (3) a refrigerant leak. (4) the compressor does not work straight through the compressor power, still does not work like that described thermal relay or compressor burn must be replaced thermal relay or compressor. 3, the machine does not heat (1) burn temperature control unit and the need to replace the contactor. (2) heating pipe dehydration burn, replacement of the same power of the original heating. 4, the inside humidity is lower than a given value unhumidified (1) Check if the given value is correct, then switch on the thermostat dial to the instrument off, to see if the spray, if you do not spray, indicating faulty humidifiers. (2) When the number of significant value is below a given value, whether wet control instrument light turns red, as the same shall be transferred back to the small difference between the appropriate, should be checked to red without a humidifier humidifier. (3) if the humidifier does not work, we should first check whether the transducer scale, impurities, the transducer must be kept clean, whether Furthermore tank without water. (4) temperature controller output signal should not check the meter, temperature display is not the case as 01-10% when unusual circumstances, with a dry cloth to remove water stains on the probe sensor, which can be displayed properly. (5) magnetic tape imprecise method by heating the magnetic strip widening (with a hair dryer) (6) Box bile leaks with epoxy adhesive or plastic welding. Seven, maintain a humidifier, humidifier when not in use, set the power switch off, unplug it. 2, the following conditions must be cleaned when the humidifier: (1) appear unpleasant odor. (2) fog mist spray is normal but not out. (3) little or no hair spray mist. 3, how to clean the humidifier (1) First remove the cap when the humidifier clean, do not soak in water for the humidifier. (2) Do not use detergent, kerosene, alcohol or glass furniture, chemical polishing agent, can not use more than 50 ℃ hot water. Users Troubleshooting Self-Test Failure table exclude meter heated rear temperature probe shake off or heating pipe damage. LED does not light bulbs damaged or power connection is true, temperature controller fuse is blown. Do not open the door when the sensitivity is poor start. Box bile leaks with epoxy adhesive. Humidifier humidifier is not normal fuse replacement. No water discharge valve is not cooling duct obstruction or blockage pipeline leak in transit, re-evacuated, fluoride is not heated electric tube wiring is damaged or shake off. Door seal lax heating method with the magnetic strip widening, the solution (with a hair dryer) |
Admin>>>
You are the 13347 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Rui Heng Test Instrument All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13347 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Rui Heng Test Instrument All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility