Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13636241

- Product Categories
- Friendly Links
Information Name: | Standard temperature and humidity curing box |
Published: | 2015-01-23 |
Validity: | 0 |
Specifications: | YH-40B / 60B / 90B |
Quantity: | 10000.00 |
Price Description: | |
Detailed Product Description: | Concrete Curing Concrete Curing Box Box specializes in supplying concrete curing boxes and other products, please contact us concrete curing box YH-40B Standard temperature and humidity curing box standard curing box with automatic temperature and humidity control, dual digital display temperature display, humidity, ultrasonic humidifier, use of imported stainless steel liner. Technical parameters: 1. Inner Dimensions: 700 × 550 × 1100 (mm) 2. Capacity: 40 sets of soft training tryout tryout Concrete 150 × 150 30 sets of 3. Thermostat range: 0-50 ℃ adjustable Accuracy: 20 ℃ ± 1 ℃ 4. humidity range: ≥90% adjustable 5. Compressor Power: 165W 6. Heater: 600W 7. Nebulizer: 15W 8. inlet valve: 12W 9. Weight: 150Kg YH-42B This new type of constant temperature and humidity constant temperature and humidity curing box has been the national conservation tank (patent number: 952324091). Automatic control, dual digital display shows the temperature, humidity, the appearance of new technology, glass sliding door, can be visually specimen liner made of stainless steel, and also with circulating air, drip, ultrasonic humidification, and other functions. Technical parameters: 1. Internal Dimensions: 1000 * 400 * 960 (mm) 2. Capacity: 5 layers of soft training tryout * 7 = 35 sets of concrete test mode 150 * 150 20 sets of 3. Thermostat range: 0-50 ℃ adjustable Accuracy: 20 ℃ ± 1 ℃ 4. humidity range: ≥90% adjustable 5. Compressor Power: 175 Watts 6 Heater: 600 watts 7. Nebulizer: 15 watts 8. Weight: 160Kg YH-60B-type thermostat Constant temperature and humidity conservation tank wet curing box with automatic control, dual digital display shows ultrasonic humidifier, all stainless steel liner. Technical parameters: 1. Inner Dimensions: 920 * 650 * 1100 (mm) Capacity: 60 sets of soft concrete practice tryout tryout 150 * 150 45 sets of 3. Thermostat range: 0-50 ℃ adjustable Accuracy: 20 ℃ ± 1 ℃ 4. humidity range: ≥90% adjustable 5. Compressor Power: 175 Watts 6. Heater: 600 watts 7. Nebulizer: 15 watts 8. Weight: 200Kg YH-80B model based on temperature and humidity curing box the user's requirements, in order to facilitate the conservation of cement, concrete test specimen meet national standards. I created a new special plant conservation tank 80B constant temperature and humidity to meet the relatively large body of customers try the box for ultrasonic humidification function, all stainless steel liner processing. Technical parameters: 1. Liner Size: 1650 * 580 * 1350mm 2. Capacity: 150 * 150 * 150 concrete test block 180 3. Thermostat range: 0-50 ℃ adjustable Accuracy: 20 ℃ ± 1 ℃ 4. humidistat Range: ≥90% adjustable 5. Cooling power: 145 watts * 26 Heater: 1000 W 7. humidification power: 45 watts 8. Weight: 220Kg YH-90B type conservation tank temperature and humidity according to the user's requirements, in order to facilitate curing cement, concrete test specimen meet national standards. I created a new special plant conservation tank 90B constant temperature and humidity to meet the relatively large body of customers try the box for ultrasonic humidification function, all stainless steel liner processing. Technical parameters: 1. Liner Size: 1450 * 580 * 1350mm 2. Concrete capacity: 150 * 150 test block 150 3. Thermostat range: 0-50 ℃ adjustable Accuracy: 20 ℃ ± 1 ℃ 4. humidity range: ≥90% adjustable 5. Cooling power: 145 watts * 26 Heater: 1000 W 7. humidification power: 45 watts 8. Weight: 350Kg 2. instruments placed after steady, you should check the door switch is flexible, electrical, refrigeration, etc. parts for damage. 3. The inside layer of the tank with water to the end of the shelf below, electric control over 2cm, the door opened to fill the tank filled with distilled water in the humidifier, the temperature inside another box of wet and dry plastic ball filled with water, and put gauze soak into the water. 4. Plug the power plug into 220V outlet has a good grounding in, press the power switch, the instrument automatically enter the working state. 5. The instrument has been incorporated into the factory standard setting process, temperature control is 20.0 ℃ ± 1.0 ℃, humidity control value of 95% ± 1.5%, no special requirements, you can not change the control program, otherwise it will likely temperature control, control humidity are outside the range, such as the need to change the control value data, you can modify the program according to the temperature controller manual. Concrete Curing Box smart meter parameter settings: :( factory standard instrument parameters programmed) a temperature control value 20.0 ℃ 2, temperature control limit (to control the value of the base) + 1 ℃ 3, humidity control value of 95% 4, the temperature lower control limit (to control the value of the reference) -0.5 ℃ 5, humidity control limit (to control the value of the benchmark) 1% 6, humidity control limit (to control the value of the benchmark) 1% concrete curing box structure: box with both internal and external layer, from outside the box and inside the box, outside the box of high quality cold-rolled steel plate, stainless steel plate inside the cabinet, shelves made of stainless steel profiles, good corrosion resistance. Within the cabinet below the tank for heating and auxiliary humidifier, ultrasonic humidifier humidifier instrument-based systems, water heating evaporation, supplemented by automatic temperature control system and control humidity meter instrument at a given temperature, humidity refrigeration heating and humidifying the implementation of automatic switching, inside temperature and humidity displayed by the meter number. Concrete Curing Box works: Temperature: When the inside temperature is lower than the lower limit setpoint temperature controller, the temperature controller output signal instruction electric heating original start work, and vice versa when the temperature is higher than the upper limit of a given value, temperature controller instruction refrigeration system works, when the inside temperature reaches the required specifications, automatically stop heating or cooling. Wet control: Using ultrasonic humidifier humidifier can guarantee inside humidity reaches ≥95%, by the temperature automatically controlled humidification device, when the humidity is <95%, temperature controller instruction humidifier working to achieve the return difference After automatically stop working, the difference should be adjusted back at 0-1 ℃, easy to be too large. Concrete curing box Caution: 1. conservation tank should be used in well-ventilated, dry, smooth, non-corrosive environment, daily use to keep the water level in the tank, humidifier to ensure normal use. 2. conservation tank in place, the need still 24 hours before being powered on, the voltage is lower than 160V or higher than allowed 240V, voltage instability will burn control device, you must use power supply. 3. The compressor can not start frequently, cooling power or stop work must be spaced five minutes, and then began the second start, in order to avoid damage to the compressor. 4. The device allowed upside avoid mixed refrigerant compressor lubricants and damaged refrigeration unit. Not tilted 45 degrees 5. handling. 6. Before the insulation test, in order to avoid the risk of leakage. 7. Add the water tank is 40 ℃ best use of concrete curing box: 1. Unpack the concrete curing box packaging, will host placed in a dry place at ambient temperature 2 ~ 38 ℃, relative humidity less than 85% , around without a strong vibration and strong electromagnetic fields affect the room. 2. Open the main entrance of removing concrete curing box studio ultrasonic humidifier, and humidifier filled with water inside. 3. Open the door, will be placed on the side door humidifier board table, turn the humidifier power, turn the humidifier humidifier work to the maximum. 4. Place the bottom of the working chamber filled with water, add the following to the end of shelf layer, heating pipes over 2cm. The conservation of the specimen is placed on a shelf. 5. The concrete curing box is powered on, press the power switch, the heating tube into the working condition will set the temperature rose to set the value of 20 ℃. 6. the concrete curing box by the intelligent instrument control heating systems, cooling systems and humidification systems to keep the temperature and humidity constant, for cement and concrete specimens standard curing temperature and humidity, the liner made of imported stainless steel plate, spray ultrasonic humidifier, high-power compressors, vacuum glass double doors, intelligent digital instrumentation and control of temperature and humidity can be an external micro-printer, the laboratory, the ideal equipment quality inspection center for the conservation of the concrete specimen. To provide you with sales hotline: 15831791941 concrete curing box Technical parameters: 1. Temperature accuracy: ± 0.1 ℃ 2. inside temperature difference: ≤ ± 2 ℃ 3. humidity control: ≥ 95% (adjustable) 4. Working voltage : 220V ± 10% 5. Heating power: 600W 6. Compressor power 158W 7. Internal dimensions: SHBY-40B type: 650 × 500 × 1150mm SHBY-60B Type: 1250 × 500 × 1150mm SHBY-90B Type: 1450 × 650 × 1150mm 8. can put concrete specimens (standard test block 150 × 150 × 150mm): SHBY-40B type can be placed 20 groups SHBY-60B type can be placed 40 groups SHBY-90B type can be placed 60 groups of concrete curing box use: 1. When should plant this instrument has been incorporated into the standard-setting process, temperature control is 20.0 ℃ ± 1.0 ℃, humidity control value of 95% ± 1.5%, no special requirements, you can not change the control program, otherwise it will likely temperature , control humidity are outside the range, such as the need to change the value of the data control, temperature control device in accordance with the instructions to modify the program. 7. When the temperature is below the set temperature is higher than 20 ℃, intelligent instrument control heating tube stop heating, refrigeration compressor start while controlling the temperature dropped to 20 ℃; when the temperature is below 20 ℃, instrument control compressor stops work, and start heating pipe, the temperature rose to 20 ℃, this cycle the temperature constant at 20 ℃, humidity control is also true. Concrete Curing Box Troubleshooting: Troubleshooting no reason meter heated rear temperature probe shake off or heating pipe damage. LED does not light bulbs damaged or power connection is true, temperature controller fuse is blown. Do not open the door when the sensitivity is poor start. Box bile leaks with epoxy adhesive. Humidifier humidifier is not normal fuse replacement. No water discharge valve is not cooling duct obstruction or blockage pipeline leak in transit, re-evacuated, fluoride is not heated electric tube wiring is damaged or shake off. Door seal lax heating method with the magnetic strip widening, the solution (with a hair dryer) no matter what kind of equipment, technical preparation is to understand the basic situation of the device, including the works, the main purpose, the basic technical parameters The basic structure, operation points, security devices, and other maintenance points, the main way to prepare is to read technical specification of the device and the device-under-test relevant national standards. To provide you with concrete curing box full compliance with national standards (national standards prescribed by the department that is in charge of materials and test methods). I plant sales of equipment to implement concrete curing box inside seven days on the basis of secondary sales support no reason to return, one year quality warranty, make customers feel comfortable buying. Sales Hotline: 15831791941 magnetic fields affect the indoor use. 2. The instrument placed smoothly, it should check the door switch is flexible, electrical, refrigeration and other components for damage. 3. The inside layer of the tank with water to the end of the shelf below, electric control over 2cm, the door opened to fill the tank filled with distilled water in the humidifier, the temperature inside another box of wet and dry plastic ball filled with water, and put gauze soak into the water. 4. Plug the power plug into 220V outlet has a good grounding in, press the power switch, the instrument automatically enter the working state. 5. The instrument has been incorporated into the factory standard setting process, temperature control is 20.0 ℃ ± 1.0 ℃, humidity control value of 95% ± 1.5%, no special requirements, you can not change the control program, otherwise it will likely temperature control, control humidity are outside the range, such as the need to change the control value data, you can modify the program according to the temperature controller manual. Concrete Curing Box smart meter parameter settings: :( factory standard instrument parameters programmed) a temperature control value 20.0 ℃ 2, temperature control limit (to control the value of the base) + 1 ℃ 3, humidity control value of 95% 4, the temperature lower control limit (to control the value of the reference) -0.5 ℃ 5, humidity control limit (to control the value of the benchmark) 1% 6, humidity control limit (to control the value of the benchmark) 1% concrete curing box structure: box with both internal and external layer, from outside the box and inside the box, outside the box of high quality cold-rolled steel plate, stainless steel plate inside the cabinet, shelves made of stainless steel profiles, good corrosion resistance. Within the cabinet below the tank for heating and auxiliary humidifier, ultrasonic humidifier humidifier instrument-based systems, water heating evaporation, supplemented by automatic temperature control system and control humidity meter instrument at a given temperature, humidity refrigeration heating and humidifying the implementation of automatic switching, inside temperature and humidity displayed by the meter number. Concrete Curing Box works: Temperature: When the inside temperature is lower than the lower limit setpoint temperature controller, the temperature controller output signal instruction electric heating original start work, and vice versa when the temperature is higher than the upper limit of a given value, temperature controller instruction refrigeration system works, when the inside temperature reaches the required specifications, automatically stop heating or cooling. Wet control: Using ultrasonic humidifier humidifier can guarantee inside humidity reaches ≥95%, by the temperature automatically controlled humidification device, when the humidity is <95%, temperature controller instruction humidifier working to achieve the return difference After automatically stop working, the difference should be adjusted back at 0-1 ℃, easy to be too large. Concrete curing box Caution: 1. conservation tank should be used in well-ventilated, dry, smooth, non-corrosive environment, daily use to keep the water level in the tank, humidifier to ensure normal use. 2. conservation tank in place, the need still 24 hours before being powered on, the voltage is lower than 160V or higher than allowed 240V, voltage instability will burn control device, you must use power supply. 3. The compressor can not start frequently, cooling power or stop work must be spaced five minutes, and then began the second start, in order to avoid damage to the compressor. 4. The device allowed upside avoid mixed refrigerant compressor lubricants and damaged refrigeration unit. Not tilted 45 degrees 5. handling. 6. Before the insulation test, in order to avoid the risk of leakage. 7. Add the water tank is 40 ℃ best use of concrete curing box: 1. Unpack the concrete curing box packaging, will host placed in a dry place at ambient temperature 2 ~ 38 ℃, relative humidity less than 85% , around without a strong vibration and strong electromagnetic fields affect the room. 2. Open the main entrance of removing concrete curing box studio ultrasonic humidifier, and humidifier filled with water inside. 3. Open the door, will be placed on the side door humidifier board table, turn the humidifier power, turn the humidifier humidifier work to the maximum. 4. Place the bottom of the working chamber filled with water, add the following to the end of shelf layer, heating pipes over 2cm. The conservation of the specimen is placed on a shelf. 5. The concrete curing box is powered on, press the power switch, the heating tube into the working condition will set the temperature rose to set the value of 20 ℃. 6. the concrete curing box by the intelligent instrument control heating systems, cooling systems and humidification systems to keep the temperature and humidity constant, for cement and concrete specimens standard curing temperature and humidity, the liner made of imported stainless steel plate, spray ultrasonic humidifier, high-power compressors, vacuum glass double doors, intelligent digital instrumentation and control of temperature and humidity can be an external micro-printer, the laboratory, the ideal equipment quality inspection center for the conservation of the concrete specimen. |
Admin>>>
You are the 13347 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Rui Heng Test Instrument All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13347 visitor
Copyright © GuangDong ICP No. 10089450, Hebei Rui Heng Test Instrument All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility